Vital sign monitoring: a practical solution by a MR-compatible phonocardiography interferometric probe
| dc.contributor.author | Nedoma, Jan | |
| dc.contributor.author | Kepák, Stanislav | |
| dc.contributor.author | Čubík, Jakub | |
| dc.contributor.author | Frnda, Jaroslav | |
| dc.contributor.author | Ďurica, Marek | |
| dc.contributor.author | Fajkus, Marcel | |
| dc.contributor.author | Martinek, Radek | |
| dc.date.accessioned | 2020-02-27T09:36:13Z | |
| dc.date.available | 2020-02-27T09:36:13Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | This paper deals with the description of S-1-S-1 interval detection of the phonocardiographic signal obtained by a fiber-optic Mach-Zehnder interferometer. A non-invasive measuring probe encapsulated in a bicomponent (base and catalyst) entitled Zhermack ZA 50 LT was designed. The probe is immune to the electromagnetic interferences (EMI) and therefore can be operated under strong magnetic fields. The laboratory results (obtained from 8 volunteers) were compared to the reference electrocardiograph (ECG) signal and evaluated by an objective Bland-Altman (B-A) method. Based on the results, it is possible to say that the S-1-S-1 interval detection with the presented fiber-optic interferometric probe is as reliable as the measurement of time between the R-R wave of the ECG signal since the B-A analysis resulted in 95.59 % samples laid in +/- 1.96 SD. The test carried out in a real Magnetic Resonance Imaging (MRI) environment demonstrated that the presence of the probe in the MRI scanner does not affect the quality of this imaging modality. The developed sensor can be suitable for cardiac triggering. | cs |
| dc.description.firstpage | 656 | cs |
| dc.description.issue | 11-12 | cs |
| dc.description.lastpage | 662 | cs |
| dc.description.source | Web of Science | cs |
| dc.description.volume | 21 | cs |
| dc.identifier.citation | Journal of Optoelectronics and Advanced Materials. 2019, vol. 21, issue 11-12, p. 656-662. | cs |
| dc.identifier.issn | 1454-4164 | |
| dc.identifier.issn | 1841-7132 | |
| dc.identifier.uri | http://hdl.handle.net/10084/139331 | |
| dc.identifier.wos | 000512350200002 | |
| dc.language.iso | en | cs |
| dc.publisher | INOE | cs |
| dc.relation.ispartofseries | Journal of Optoelectronics and Advanced Materials | cs |
| dc.relation.uri | https://joam.inoe.ro/articles/vital-sign-monitoring-a-practical-solution-by-a-mr-compatible-phonocardiography-interferometric-probe/fulltext | cs |
| dc.subject | fiber-optic sensor | cs |
| dc.subject | interferometer | cs |
| dc.subject | physiological parameters monitoring | cs |
| dc.title | Vital sign monitoring: a practical solution by a MR-compatible phonocardiography interferometric probe | cs |
| dc.type | article | cs |
| dc.type.status | Peer-reviewed | cs |
Files
License bundle
1 - 1 out of 1 results
Loading...
- Name:
- license.txt
- Size:
- 718 B
- Format:
- Item-specific license agreed upon to submission
- Description:
Collections
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Publikační činnost Katedry telekomunikačních technologií / Publications of Department of Telecommunications (440)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Publikační činnost Katedry telekomunikačních technologií / Publications of Department of Telecommunications (440)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals