Abstract
We report on a microfluidic system formed by 200 nl water droplets, encapsulated by a 600 nl mineral oil placed on a hydrophobically coated glass microscope cover slip. The micromachined heater underneath the glass was able to heat up the sample at a heating rate of 650 °C/s, heating the water sample up to 200 °C in less than 2 s. The sample/glass and the sample/oil interface did not have nucleation centers, showing that the sample reached a superheated stage without the necessity of being pressurized to suppress boiling. This method can be utilized for various applications currently being conducted in autoclaves.
Description
Subject(s)
Citation
Applied Physics Letters. 2015, vol. 106, issue 2, art. no. 024104.