| dc.description.abstract | This paper deals with problematic of Electromagnetic Compatibility of Implantable Pacemaker. The ambient electromagnetic field can negatively influence the pacemaker functionality and also the wireless communication between its programmer and device. Electromagnetic compatibility parameters are tested by direct induction of interference signal to the inputs of cardiac pacemaker according to technical specification. The experimental tests were also made by generating of interference radio frequency signals to disturb the wireless telemetry communication. | en |
| dc.description.abstract-en | Przeanalizowano problem kompatybilności elektromagnetycznej przy pracy stymulatora serca. Zewnętrzne pole elektromagnetyczne może negatywnie wpływać na pracę stymulatora i na komunikację bezprzewodową z programatorem. Przeprowadzono eksperymenty z bez[pośrednim zakłóceniem pracy zewnętrzną falą elektromagnetyczną. | en |
| dc.format.extent | 2292733 bytes | cs |
| dc.format.mimetype | application/pdf | cs |
| dc.identifier.citation | Przegląd elektrotechniczny. 2011, r. 87, nr. 5, s. 265-268. | en |
| dc.identifier.issn | 0033-2097 | |
| dc.identifier.location | Není ve fondu ÚK | en |
| dc.identifier.uri | http://hdl.handle.net/10084/84563 | |
| dc.identifier.wos | 000290207900064 | |
| dc.language.iso | en | en |
| dc.publisher | Sigma Not | en |
| dc.relation.ispartofseries | Przegląd elektrotechniczny | en |
| dc.relation.uri | http://pe.org.pl/articles/2011/5/65.pdf | |
| dc.rights.access | openAccess | |
| dc.subject | measurement | en |
| dc.subject | implantable pacemaker | en |
| dc.subject | electromagnetic compatibility | en |
| dc.subject | disturbing signal | en |
| dc.subject | stymulator serca | en |
| dc.subject | kompatybilność elektromagnetyczna | en |
| dc.title | Measurement and analysis EMC parameters of implantable pacemaker | en |
| dc.title.alternative | Pomiary i analiza kompatybilności elektromagnetycznej stymulatora serca | en |
| dc.type | article | en |
| dc.type.version | publishedVersion |
Files
Original bundle
1 - 1 out of 1 results
Loading...
- Name:
- przeglad-elektrotech-2011-87-5-265-penhaker.pdf
- Size:
- 2.19 MB
- Format:
- Adobe Portable Document Format
- Description:
- publishedVersion
License bundle
1 - 1 out of 1 results
Loading...
- Name:
- license.txt
- Size:
- 1.8 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
Collections
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science
OpenAIRE
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals
OpenAIRE
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals