A low-cost system for seismocardiography-based cardiac triggering: A practical solution for cardiovascular magnetic resonance imaging at 3 tesla

dc.contributor.authorMartinek, Radek
dc.contributor.authorBrablík, Jindřich
dc.contributor.authorKolařík, Jakub
dc.contributor.authorLádrová, Martina
dc.contributor.authorNedoma, Jan
dc.contributor.authorJaroš, René
dc.contributor.authorŠoustek, Lukáš
dc.contributor.authorKahánková, Radana
dc.contributor.authorFajkus, Marcel
dc.contributor.authorVojtíšek, Lubomír
dc.contributor.authorHanzlíková, Pavla
dc.contributor.authorKrupa, Petr
dc.date.accessioned2020-01-10T08:13:59Z
dc.date.available2020-01-10T08:13:59Z
dc.date.issued2019
dc.description.abstractThis study describes a pilot clinical validation of a new low-cost system for the continuous monitoring of the human body's cardiorespiratory activities within the magnetic resonance examination area. This study primarily focuses on monitoring cardiac activity and the related cardiac triggering. The patented system tested by the authors is based on seismocardiography (SCG). The study was conducted on 18 subjects on a Siemens Prisma 3T MR scanner. Standard anatomical and diffusion sequences were used to test cardiac activity monitoring. A wide range of commonly used diagnostic sequences were used to test imaging of the heart by means of cardiac triggering. System functionality was verified against a commercially available electrocardiography (ECG) system. Monitoring of cardiac activity (detection of the R-R interval in ECG and the AO-AO interval in SCG) was objectively evaluated by determining the overall probability of correct detection (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV, i.e. F1. Imaging quality control using Cardiac Triggering was performed by subjective evaluation of images by the physicians. The study conducted clearly confirmed the functionality of the system in terms of continuous cardiac activity monitoring. In all 18 subjects, a mean PPV > 99% was achieved; F1 > 99 %; SE > 99 %; ACC > 98 %; 1.96 sigma < 3.5 bpm. Also, Cardiac Triggering functionality was confirmed by the physicians on the basis of analyzing cardiac images using the T1/T2 balanced echo sequences and the T1 flash sequence measured natively.cs
dc.description.firstpage118608cs
dc.description.lastpage118629cs
dc.description.sourceWeb of Sciencecs
dc.description.volume7cs
dc.identifier.citationIEEE Access. 2019, vol. 7, p. 118608-118629.cs
dc.identifier.doi10.1109/ACCESS.2019.2936184
dc.identifier.issn2169-3536
dc.identifier.urihttp://hdl.handle.net/10084/139058
dc.identifier.wos000498548500001
dc.language.isoencs
dc.publisherIEEEcs
dc.relation.ispartofseriesIEEE Accesscs
dc.relation.urihttps://doi.org/10.1109/ACCESS.2019.2936184cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectseismocardiography-based cardiac triggeringcs
dc.subjectseismocardiography (SCG)cs
dc.subjectsiemens prisma 3Tcs
dc.subjectmonitor patient vital signs during MRIcs
dc.subjectcardiac magnetic resonance imaging (CMRI)cs
dc.titleA low-cost system for seismocardiography-based cardiac triggering: A practical solution for cardiovascular magnetic resonance imaging at 3 teslacs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
2169-3536-2019v7p118608.pdf
Size:
6.84 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: