dc.description.abstractThis study aims to point out the main drawback with respect to the design of simulated body environments. Three media commonly used for the simulation of the identical body environment were selected, i.e., Kokubo's simulated body fluid that simulates the inorganic component of human blood plasma, human blood plasma, and phosphate buffer saline. A comparison was performed of the effects of the media on collagen scaffolds. The mechanical and structural effects of the media were determined via the application of compression mechanical tests, the determination of mass loss, and image and micro-CT analyses. The adsorption of various components from the media was characterized employing energy-dispersive spectrometry. The phase composition of the materials before and after exposure was determined using X-ray diffraction. Infrared spectroscopy was employed for the interpretation of changes in the collagen secondary structure. Major differences in terms of the mechanical properties and mass loss were observed between the three media. Conversely, only minor structural changes were detected. Since no general recommendation exists for selecting the simulated body environment, it is necessary to avoid the simplification of the results and, ideally, to utilize alternative methods to describe the various aspects of degradation processes that occur in the media.cs
dc.description.firstpageart. no. 4388cs
dc.description.issue16cs
dc.description.sourceWeb of Sciencecs
dc.description.volume14cs
dc.identifier.citationMaterials. 2021, vol. 14, issue 16, art. no. 4388.cs
dc.identifier.doi10.3390/ma14164388
dc.identifier.issn1996-1944
dc.identifier.urihttp://hdl.handle.net/10084/146062
dc.identifier.wos000689353200001
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesMaterialscs
dc.relation.urihttps://doi.org/10.3390/ma14164388cs
dc.rights© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectsimulated body fluidcs
dc.subjectcollagencs
dc.subjectblood plasmacs
dc.subjectmechanical propertiescs
dc.subjectstructural parameterscs
dc.subjectporositycs
dc.subjectmass losscs
dc.subjectscaffoldcs
dc.subjectmicro-CTcs
dc.subjectXRDcs
dc.titleVarious simulated body fluids lead to significant differences in collagen tissue engineering scaffoldscs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1996-1944-2021v14i16an4388.pdf
Size:
6.93 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: