dc.description.abstractAn original method for estimating fouled deposit thickness on the inside surfaces of natural gas cooler tubes is presented. This method does not require opening and inspecting a cooler as it is based on the measurement of gas cooling degree, i.e. the gas temperature difference between the cooler inlet and discharge. The deposit layer on the internal heat transfer surfaces is of semi-liquid consistency and its thermal conductivity coefficient has not been investigated until now. This paper describes the experimental determination of the deposit thermal conductivity coefficient. This parameter enables determination of a cooler’s performance as a function of current deposit thickness. Practical application of the method is illustrated in the case of CH_R cooler working in the KS01 compressor station in Vel’ké Kapušany, Slovakia. For this type of cooler, a diagram for deposit thickness as a function of the gas cooling degree is presented.cs
dc.description.firstpage2935cs
dc.description.issue11cs
dc.description.lastpage2941cs
dc.description.sourceWeb of Sciencecs
dc.description.volume25cs
dc.identifier.citationJournal of Mechanical Science and Technology. 2011, vol. 25, issue 11, s. 2935-2941.cs
dc.identifier.doi10.1007/s12206-011-0702-7
dc.identifier.issn1738-494X
dc.identifier.issn1976-3824
dc.identifier.locationNení ve fondu ÚKcs
dc.identifier.urihttp://hdl.handle.net/10084/89852
dc.identifier.wos000296926200025
dc.language.isoencs
dc.publisherSpringercs
dc.relation.ispartofseriesJournal of Mechanical Science and Technologycs
dc.relation.urihttps://doi.org/10.1007/s12206-011-0702-7cs
dc.subjectnatural gascs
dc.subjectcoolercs
dc.subjectsediment thicknesscs
dc.subjectoverall heat transfer coefficientcs
dc.titleDetermination of deposit thickness in natural gas cooler based on the measurements of gas cooling degreecs