Application of Bernoulli process-based charts to electronic assembly
Loading...
Downloads
2
Date issued
Journal Title
Journal ISSN
Volume Title
Publisher
Intech
Location
Signature
License
Abstract
The application of protective gel, which is a subprocess
of the electronic assembly of the exhaust gas recirculation
sensor, is a highly capable process with the fraction
of nonconforming units as low as 200 ppm. Every unit is
inspected immediately after gel application. The conventional
Shewhart chart is of no use here, and the approach
based on the Bernoulli process is therefore
considered. The number of conforming items in a row
until the occurrence of first or the r-th nonconforming is
determined and CCC-r, CCC-r EWMA, and CCC CUSUM
charts are applied. The aim of the control is to detect the
process deterioration, and so the one-sided charts are
used. So that the charts based on the geometric or
negative binomial distribution can be compared, their
performance is assessed through the average number of
inspected units until a signal (ANOS). Our study
confirmed that CCC-r EWMA and CCC CUSUM are able
to detect the process shift more quickly than the CCC-r
chart. Of the two charts, the first is easier to construct.
Description
Subject(s)
CCC-r, CCC-CUSUM, CCC-r EWMA, highly capable process, ANOS
Citation
International Journal of Engineering Business Management. 2015, vol. 7, art. no. 14.