Reduction of pollutant emissions from the combustion of hard coal after the addition of smokeless coal

Loading...
Thumbnail Image

Downloads

0

Date issued

Journal Title

Journal ISSN

Volume Title

Publisher

Sigma-Not

Location

Signature

Abstract

The water boiler was fed with hard coal or smokeless coal-contg. mixts. in mass ratios of 85/15 and 70/30. The compn. of exhaust gases was analyzed for the content of CO, CO2, NOx, SO2, PM2.5, PM10 and polycyclic aromatic hydrocarbons. A significant redn. of emission factors was obsd. during the combustion of blends with smokeless coal as compared to the combustion of hard coal.

Description

Subject(s)

Citation

Przemysł Chemiczny. 2020, vol. 99, issue 11, p. 1610-1615.