Fiber-optic breathing mask: An alternative solution for MRI respiratory triggering
| dc.contributor.author | Nedoma, Jan | |
| dc.contributor.author | Kostelanský, Michal | |
| dc.contributor.author | Vilímek, Dominik | |
| dc.contributor.author | Ládrová, Martina | |
| dc.contributor.author | Martinek, Radek | |
| dc.contributor.author | Kahánková, Radana | |
| dc.contributor.author | Fajkus, Marcel | |
| dc.contributor.author | Brablík, Jindřich | |
| dc.contributor.author | Hanzlíková, Pavla | |
| dc.contributor.author | Mohammed, Mazin Abed | |
| dc.contributor.author | Behbehani, Khosrow | |
| dc.date.accessioned | 2022-07-13T12:22:32Z | |
| dc.date.available | 2022-07-13T12:22:32Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | This article provides the outcomes of complex testing of a novel low-cost and safe breathing sensor using fiber-optic technology under real magnetic resonance (MR) examination at 3 T. The sensor consists of the Bragg grating embedded into an oxygen breathing mask [i.e., fiber-optic breathing mask (FOBM)], thus minimizing movement artifacts and preventing MR interference. The obtained triggered MR images were evaluated using both objective and subjective image analysis methods, such as signal-to-noise ratio, contrast-noise ratio, and the analysis performed by radiologists. The system was compared with Siemens Prisma Respiratory Reference based on the navigator technique and pneumatic respiratory belt. Image quality assessment provided by radiologist experts shows that the FOBM approach provides reliable and accurate results since the overall image quality reached an average score of 3.3 +/- 0.4, 3.7 +/- 0.5, and 3.8 +/- 0.2 for FOBM, Siemens respiratory reference, and respiratory belts, respectively. | cs |
| dc.description.firstpage | art. no. 7003613 | cs |
| dc.description.source | Web of Science | cs |
| dc.description.volume | 71 | cs |
| dc.identifier.citation | IEEE Transactions on Instrumentation and Measurement. 2022, vol. 71, art. no. 7003613. | cs |
| dc.identifier.doi | 10.1109/TIM.2022.3168933 | |
| dc.identifier.issn | 0018-9456 | |
| dc.identifier.issn | 1557-9662 | |
| dc.identifier.uri | http://hdl.handle.net/10084/146378 | |
| dc.identifier.wos | 000791768500017 | |
| dc.language.iso | en | cs |
| dc.publisher | IEEE | cs |
| dc.relation.ispartofseries | IEEE Transactions on Instrumentation and Measurement | cs |
| dc.relation.uri | https://doi.org/10.1109/TIM.2022.3168933 | cs |
| dc.rights | Copyright © 2022, IEEE | cs |
| dc.subject | alternative sensors | cs |
| dc.subject | fiber-optic sensor | cs |
| dc.subject | magnetic resonance (MR) respiratory triggering | cs |
| dc.title | Fiber-optic breathing mask: An alternative solution for MRI respiratory triggering | cs |
| dc.type | article | cs |
| dc.type.status | Peer-reviewed | cs |
Files
License bundle
1 - 1 out of 1 results
Loading...
- Name:
- license.txt
- Size:
- 718 B
- Format:
- Item-specific license agreed upon to submission
- Description:
Collections
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Publikační činnost Katedry telekomunikačních technologií / Publications of Department of Telecommunications (440)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Publikační činnost Katedry telekomunikačních technologií / Publications of Department of Telecommunications (440)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals