Kontrola výkonu a návrh rekonstrukce paroproudé vývěvy kondensátoru parní turbiny

Loading...
Thumbnail Image

Downloads

Date issued

Authors

Jaracz, Roman

Journal Title

Journal ISSN

Volume Title

Publisher

Vysoká škola báňská - Technická univerzita Ostrava

Location

ÚK/Sklad diplomových prací

Signature

200905558

Abstract

This thesis deals with problems about two-stage steam-jet injektor insufficient air exhausting out of steam condenser. Computational, theoretical part of work is setting against to real values. In next stage there are propose constructional arrangements to steam-jet ejector present configuration. Just according to above mentioned comparison between ideal and actual values.

Description

Import 31/08/2009

Subject(s)

steam condenser, steam-air ejector

Citation