dc.description.abstractThe work has been aimed to create an overview of available and used methods and ways to determine the concentration of glucose in body fluids, especially from a technical point of view. It also provides an overview of the clinical features of these methods. The survey found that today's market offers a large number of options and approaches to the issue. There are accurate reference laboratory methods, self-monitoring methods for measuring glucose levels using glucometers, or continuous methods for daily monitoring of blood glucose trends and for insulin pump control. However, it must not be forgotten that the development of full closure of feedback is still not complete today. Individual methods cannot always be compared with each other, precisely because of the focus and the use of these methods. Choosing the right method of blood glucose levels in the body measuring can help patients to manage their diabetes mellitus. The methods listed in the overview are divided in terms of measurement continuity and further according to the invasiveness of the method. Finally, the issues of accuracy in the detection of glycaemia variability and the possibility of further development of these methods are discussed, as it is clear from the survey that the development is focused mainly on continuous methods improving that get to the forefront and also on developing a biosensor that is purely non-invasive and continuous.cs
dc.description.firstpageart. no. 114348cs
dc.description.sourceWeb of Sciencecs
dc.description.volume211cs
dc.identifier.citationBiosensors & Bioelectronics. 2022, vol. 211, art. no. 114348.cs
dc.identifier.doi10.1016/j.bios.2022.114348
dc.identifier.issn0956-5663
dc.identifier.issn1873-4235
dc.identifier.urihttp://hdl.handle.net/10084/148598
dc.identifier.wos000806344000001
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofseriesBiosensors & Bioelectronicscs
dc.relation.urihttps://doi.org/10.1016/j.bios.2022.114348cs
dc.rights© 2022 The Authors. Published by Elsevier B.V.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/cs
dc.subjectglycemic controlcs
dc.subjectglucose monitoringcs
dc.subjectcontinuous glucose monitoring (CGM)cs
dc.subjectglucose selfmonitoring (SMBG)cs
dc.subjectnon-invasive measurement glucosecs
dc.titleReview of present method of glucose from human blood and body fluids assessmentcs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
0956-5663-2022v211an114348.pdf
Size:
4.01 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: