Effect of testing conditions on the mechanical response of aortic tissues from planar biaxial experiments: Loading protocol and specimen side

dc.contributor.authorSigaeva, Taisiya
dc.contributor.authorPolzer, Stanislav
dc.contributor.authorVitásek, Radek
dc.contributor.authorDi Martino, Elena S.
dc.date.accessioned2021-02-27T14:52:21Z
dc.date.available2021-02-27T14:52:21Z
dc.date.issued2020
dc.description.abstractThis study concerns procedural aspects of planar biaxial experiments on aortic tissues that have not been exhaustively addressed in the literature. The following questions are explored. First, is there a difference in the apparent mechanical properties if the experiments are conducted in a force-controlled regime or a displacement-controlled regime. Second, does it matter whether the deformations of the surface are tracked from one side of the tissue or the other (luminal vs. abluminal surface). The study provides answers to these questions with the help of a series of experiments on porcine aortic tissue, constitutive modelling and statistical analysis. It was found that the loading protocol does not substantially affect the constitutive response, while the surface orientation does.cs
dc.description.firstpageart. no. 103882cs
dc.description.sourceWeb of Sciencecs
dc.description.volume111cs
dc.identifier.citationJournal of the Mechanical Behavior of Biomedical Materials. 2020, vol. 111, art. no. 103882.cs
dc.identifier.doi10.1016/j.jmbbm.2020.103882
dc.identifier.issn1751-6161
dc.identifier.issn1878-0180
dc.identifier.urihttp://hdl.handle.net/10084/142892
dc.identifier.wos000575376700001
dc.language.isoencs
dc.publisherElseviercs
dc.relation.ispartofseriesJournal of the Mechanical Behavior of Biomedical Materialscs
dc.relation.urihttp://doi.org/10.1016/j.jmbbm.2020.103882cs
dc.rights© 2020 Elsevier Ltd. All rights reserved.cs
dc.subjectplanar biaxial testingcs
dc.subjectporcine aortic tissuecs
dc.subjectconstitutive modellingcs
dc.titleEffect of testing conditions on the mechanical response of aortic tissues from planar biaxial experiments: Loading protocol and specimen sidecs
dc.typearticlecs