Glucose measuring device with advanced data processing and improved strip detection
| dc.contributor.author | Jirka, Jakub | |
| dc.contributor.author | Prauzek, Michal | |
| dc.contributor.author | Stankuš, Martin | |
| dc.date.accessioned | 2013-08-16T12:22:58Z | |
| dc.date.available | 2013-08-16T12:22:58Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | People suffering from diabetes mellitus are dependent on exact blood glucose concentration information. This information is vital for their successful treatment and protection against life threatening extremely low or high blood sugar levels. Solution described in this paper integrates blood glucose evaluation and treatment recommendation, where all the information like body sensitivity to insulin and carbohydrate to insulin ratio is used to calculate recommended amount of next insulin dosage or food. This solution also supports strip with damaged insertion signal line. Device prototype had been developed and successfully tested on three subjects with diabetes I and two with diabetes II. | cs |
| dc.description.firstpage | 40 | cs |
| dc.description.issue | 1 | cs |
| dc.description.lastpage | 43 | cs |
| dc.description.source | Web of Science | cs |
| dc.description.volume | 19 | cs |
| dc.identifier.citation | Elektronika ir Elektrotechnika. 2013, vol. 19, no. 1, p. 40-43. | cs |
| dc.identifier.doi | 10.5755/j01.eee.19.1.3251 | |
| dc.identifier.issn | 1392-1215 | |
| dc.identifier.issn | 2029-5731 | |
| dc.identifier.uri | http://hdl.handle.net/10084/100645 | |
| dc.identifier.wos | 000320496200010 | |
| dc.language.iso | en | cs |
| dc.publisher | Kaunas University of Technology, Department of Electronics Engineering | cs |
| dc.relation.ispartofseries | Elektronika ir Elektrotechnika | cs |
| dc.relation.uri | http://dx.doi.org/10.5755/j01.eee.19.1.3251 | cs |
| dc.subject | data processing | cs |
| dc.subject | embedded system | cs |
| dc.subject | glucose | cs |
| dc.subject | insulin | cs |
| dc.title | Glucose measuring device with advanced data processing and improved strip detection | cs |
| dc.type | article | cs |
| dc.type.status | Peer-reviewed | cs |
Files
License bundle
1 - 1 out of 1 results
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
Collections
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals