Effects of loaded end distance and moisture content on the behavior of bolted connections in squared and round timber subjected to tension parallel to the grain

dc.contributor.authorLokaj, Antonín
dc.contributor.authorDobeš, Pavel
dc.contributor.authorSucharda, Oldřich
dc.date.accessioned2021-02-16T13:08:41Z
dc.date.available2021-02-16T13:08:41Z
dc.date.issued2020
dc.description.abstractThis article presents the results of static tests on bolted connections in squared and round timber with inserted steel plates. The experiment evaluates structural timber connections with different distances between the fastener and the loaded end at different moisture contents. Specimens were loaded by tension parallel to the grain and load-deformation diagrams were recorded. Fifty-six specimens with three different distances between the fastener and the loaded end, at different moisture contents, were tested. The results were statistically evaluated using regression analysis, complemented with load-deformation curves, and compared with calculations according to the valid standard for design of timber structures. A decrease in the evaluated load-carrying capacity with increasing moisture content was confirmed experimentally. A slight increase in the evaluated load-carrying capacity with increasing fastener distance from the loaded end was found.cs
dc.description.firstpageart. no. 5525cs
dc.description.issue23cs
dc.description.sourceWeb of Sciencecs
dc.description.volume13cs
dc.identifier.citationMaterials. 2020, vol. 13, issue 23, art. no. 5525.cs
dc.identifier.doi10.3390/ma13235525
dc.identifier.issn1996-1944
dc.identifier.urihttp://hdl.handle.net/10084/142834
dc.identifier.wos000597609700001
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesMaterialscs
dc.relation.urihttp://doi.org/10.3390/ma13235525cs
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectconnectioncs
dc.subjecttimbercs
dc.subjecttestcs
dc.subjectboltcs
dc.subjectsteel platecs
dc.subjectmoisture contentcs
dc.subjectfailurecs
dc.titleEffects of loaded end distance and moisture content on the behavior of bolted connections in squared and round timber subjected to tension parallel to the graincs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1996-1944-2020v13i23an5525.pdf
Size:
9.24 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: