Design of a measuring system for electricity quality monitoring within the SMART street lighting test polygon: Pilot study on adaptive current control strategy for three-phase shunt active power filters

dc.contributor.authorMartinek, Radek
dc.contributor.authorBilík, Petr
dc.contributor.authorBaroš, Jan
dc.contributor.authorBrablík, Jindřich
dc.contributor.authorKahánková, Radana
dc.contributor.authorJaroš, René
dc.contributor.authorDanys, Lukáš
dc.contributor.authorRzidky, Jaroslav
dc.contributor.authorWen, He
dc.date.accessioned2021-03-01T10:34:33Z
dc.date.available2021-03-01T10:34:33Z
dc.date.issued2020
dc.description.abstractThis study focuses on the design of a measuring system for monitoring the power quality within the SMART street lighting test polygon at university campuses with relation to testing an adaptive current control strategy for three-phase shunt active power filters. Unlike conventional street lighting, SMART elements are powered 24/7. Due to the electronic character of the power part of such mass appliances, there are increased problems with the power quality of the electric energy. Compared to the current concept of street lighting, there is a significant increase in the content of higher current harmonic components, which cause several problems in the distribution system. The test polygon contains 16 luminaires made by various manufacturers and mounted with various SMART components. Using the polygon control and monitoring system, dynamic load scenarios were selected. These scenarios tested the possibilities of different adaptive current control strategies for three-phase shunt active power filters to improve the power quality of electricity. This study focuses on three adaptive algorithms that respond to dynamic changes of current harmonics level in real-time. The possibility of active filter control was tested using FPGA, mainly due to the low latency of the filter control part.cs
dc.description.firstpageart. no. 1718cs
dc.description.issue6cs
dc.description.sourceWeb of Sciencecs
dc.description.volume20cs
dc.identifier.citationSensors. 2020, vol. 20, issue 6, art. no. 1718.cs
dc.identifier.doi10.3390/s20061718
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10084/142898
dc.identifier.wos000529139700176
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesSensorscs
dc.relation.urihttp://doi.org/10.3390/s20061718cs
dc.rights© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectpower quality (PQ)cs
dc.subjectshunt active power filter (SAPF)cs
dc.subjectvirtual instrumentation (VI)cs
dc.subjectBROADBANDlightcs
dc.subjectleast mean squares filter (LMS)cs
dc.subjectrecursive least squares filter (RLS)cs
dc.titleDesign of a measuring system for electricity quality monitoring within the SMART street lighting test polygon: Pilot study on adaptive current control strategy for three-phase shunt active power filterscs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1424-8220-2020v20i6an1718.pdf
Size:
11.14 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: