Finite element analysis of Ti-based knee-joint implant
Loading...
Downloads
3
Date issued
Journal Title
Journal ISSN
Volume Title
Publisher
Hrvatsko Metalurško Društvo
Location
Signature
Abstract
The focus of this paper was on finite element analysis of a PROSPON oncological knee endoprosthesis. The 3D CAD
knee joint model, the designed FE PROSPON prosthesis model into which was integrated, was created on the basis
of Visible Human Project CT scans. Analyses of stress state and contact pressures were performed in the kneebending
position within 15,4° - 69,4° hip joint flection range. The results showed that the maximum achieved stress
did not exceed the yield strength (90 MPa) of the material. The results of the stress state were in accordance with the
distribution of contact pressure.