Model and real pollutant dispersion: concentration studies by conventional analytics and by laser spectrometry
Loading...
Downloads
0
Date issued
Journal Title
Journal ISSN
Volume Title
Publisher
Taylor & Francis
Location
Není ve fondu ÚK
Signature
Abstract
The differential absorption LIDAR together with spot analyzers (infrared absorption and chemiluminescence method) was used for concentration measurements in an urban street canyon in Prague. Measurements in the real atmosphere were compared with measurements of concentration distribution inside a model. Experiments in a wind-tunnel-simulated atmosphere were carried out using laser photoacoustic spectrometry and the laser visualization method. A comparison of concentrations on the windward and leeward sides of the model and real street canyon was performed.
Description
Subject(s)
air pollution, photoacoustic spectrometry, wind tunnel, differential absorption LIDAR
Citation
International Journal of Environmental Analytical Chemistry. 2006, vol. 86, no. 12, p. 889 - 903.