Analysis of the fire properties of blown insulation from crushed straw in the buildings

dc.contributor.authorTeslík, Jiří
dc.date.accessioned2021-10-21T14:17:05Z
dc.date.available2021-10-21T14:17:05Z
dc.date.issued2021
dc.description.abstractSustainable development in civil engineering is the clear and necessary goal of the current generation. There are many possibilities for reducing the use of depletable resources. One of them is to use renewable and recyclable materials on a larger scale in the construction industry. One possibility is the application of natural thermal insulators. A typical example is a crushed straw, which is generated as agricultural waste in the Czech Republic. Due to its small dimensions and good thermal insulation parameters, this material can also be used as blown thermal insulation. The research aims to examine the fire resistance of crushed straw as blown insulation. The single-flame source fire test results, thermal attack by a single burning item (SBI) test and large-scale test of a perimeter wall segment are shown. The results show that blown insulation made of crushed straw meets the requirements of fire protection. In addition, crushed straw can be also used to protect load-bearing structures due to its behaviour. This article also shows the production process of crushed straw used as blown insulation in brief.cs
dc.description.firstpageart. no. 4336cs
dc.description.issue15cs
dc.description.sourceWeb of Sciencecs
dc.description.volume14cs
dc.identifier.citationMaterials. 2021, vol. 14, issue 15, art. no. 4336.cs
dc.identifier.doi10.3390/ma14154336
dc.identifier.issn1996-1944
dc.identifier.urihttp://hdl.handle.net/10084/145342
dc.identifier.wos000682042900001
dc.language.isoencs
dc.publisherMDPIcs
dc.relation.ispartofseriesMaterialscs
dc.relation.urihttps://doi.org/10.3390/ma14154336cs
dc.rights© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.cs
dc.rights.accessopenAccesscs
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/cs
dc.subjectcrushed strawcs
dc.subjectblown insulationcs
dc.subjectfire testcs
dc.subjectsustainabilitycs
dc.subjectfire reaction classcs
dc.subjectcivil engineeringcs
dc.titleAnalysis of the fire properties of blown insulation from crushed straw in the buildingscs
dc.typearticlecs
dc.type.statusPeer-reviewedcs
dc.type.versionpublishedVersioncs

Files

Original bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
1996-1944-2021v14i15an4336.pdf
Size:
8.35 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 out of 1 results
Loading...
Thumbnail Image
Name:
license.txt
Size:
718 B
Format:
Item-specific license agreed upon to submission
Description: