Electrical parameters measurement and testing of implantable cardioverters - defibrillators
| dc.contributor.author | Penhaker, Marek | |
| dc.contributor.author | Kašík, Vladimír | |
| dc.contributor.author | Korpas, David | |
| dc.date.accessioned | 2011-07-29T13:17:53Z | |
| dc.date.available | 2011-07-29T13:17:53Z | |
| dc.date.issued | 2011 | |
| dc.description.abstract | The aim of the work was measurement and testing of implantable cardioverter - defibrillator (ICDs) device. There was realised electronic measuring circuit which substitutes human body tissue during the device accuracy testing. This circuit enables to measure defibrillation shock discharge in the whole energy range (0.1- 41J). The presented measuring and testing procedures can easy check-up precision of parameters and functionality of embedded electronic device circuit’s part of the ICDs. Presented suggestion and results of this work can be implemented as verification procedure in various types of ICDs and also pacemakers before their implantation as well. | |
| dc.description.abstract-en | W artykule przedstawiono wpływ indukcji i częstotliwości na straty w żelazie w blachach elektrotechnicznych wykorzystywanych w dławikach pracujących w filtrach wyższych harmonicznych. Podano uogólnioną zależność pozwalającą na obliczenie strat histerezowych i wiroprądowych z uwzględnieniem zastępczej eliptycznej pętli histerezy. Otrzymane wyniki porównano z pomiarami. Wprowadzony do rozważań współczynnik An zależy w praktyce od średniej wartości indukcji występującej w przekroju poprzecznym rdzenia. Uogólniona zależność zawierająca współczynnik An może być stosowana w szerokim zakresie częstotliwości. | |
| dc.format.extent | 1217454 bytes | cs |
| dc.format.mimetype | application/pdf | cs |
| dc.identifier.citation | Przegląd elektrotechniczny. 2011, r. 87, nr. 6, s. 186-189. | cs |
| dc.identifier.issn | 0033-2097 | |
| dc.identifier.location | Není ve fondu ÚK | cs |
| dc.identifier.uri | http://hdl.handle.net/10084/89032 | |
| dc.identifier.wos | 000291257700032 | |
| dc.language.iso | en | cs |
| dc.publisher | Sigma Not | cs |
| dc.relation.ispartofseries | Przegląd elektrotechniczny | cs |
| dc.relation.uri | http://pe.org.pl/articles/2011/6/32.pdf | |
| dc.rights.access | openAccess | |
| dc.subject | implantable Cardioverter | |
| dc.subject | defibrillation shock | |
| dc.subject | energy | |
| dc.subject | measurement | |
| dc.subject | programmer | |
| dc.subject | defibrylator | |
| dc.subject | kardiostymulatory | |
| dc.title | Electrical parameters measurement and testing of implantable cardioverters - defibrillators | cs |
| dc.title.alternative | Pomiar parametrów elektrycznych i testowanie implantowanych cardio-stymulatorów | |
| dc.type | article | cs |
| dc.type.version | publishedVersion |
Files
Original bundle
1 - 1 out of 1 results
Loading...
- Name:
- przeglad-elektrotech-2011-87-6-186-penhaker.pdf
- Size:
- 1.16 MB
- Format:
- Adobe Portable Document Format
- Description:
- publishedVersion
License bundle
1 - 1 out of 1 results
Loading...
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
Collections
Publikační činnost VŠB-TUO ve Web of Science / Publications of VŠB-TUO in Web of Science
OpenAIRE
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals
OpenAIRE
Publikační činnost Katedry kybernetiky a biomedicínského inženýrství / Publications of Department of Cybernetics and Biomedical Engineering (450)
Články z časopisů s impakt faktorem / Articles from Impact Factor Journals